VRV AURORA
Applications
Features
- VRF Industry’s first air cooled system that delivers heating down to -22°F (-30°C) as standard
- Daikin’s patented inverter based vapor injection compressor delivers high heating capacity of up to 100% at 0°F (-18°C), up to 85% at -13°F (-25°C) and up to 60% at -22°F(-30°C)
- Optimized efficiencies delivered by dedicated all-inverter compressors and inverter fan motors
- Refrigerant-cooled efficient and stable inverter board operation, independent of ambient conditions
- Hot gas base pan circuit allows installation without an additional drain pan heater
- Designed to provide continuous heating during defrost and oil return**
- Engineered with patented Daikin vapor injection compressor for optimized part load efficiencies
- Added peace of mind with Auto Changeover ability to back up (auxiliary) heat
- Long pipe lengths up to 1640 ft total and ability to connect up to 41*** indoor units with up to 100 ft vertical separation between indoor units provides design and installation flexibility
- Corrosion resistant, 1000 hours salt spray tested Daikin PE blue fin heat exchanger
- Ships factory standard with coil guard
Lineup
Daikin’s new VRV AURORA offers a simplified range of condenser unit combinations. Ranging from 6 to 38 tons in a single system, all versions of the VRV Aurora feature inverter controlled compressors and the new Variable Refrigerant Temperature control cycle for improved seasonal efficiency. Available in 208-230V or 460V versions.
Capacity (TON) | 6 | 8 | 10 | 12 | 16 | 20 | |
---|---|---|---|---|---|---|---|
208-230V & 460V | No. of Outdoor Units | 1 | 1 | 1 | 1 | 2 | 2 |
Max No. of Indoor Units | 12 | 16 | 20 | 25 | 33 | 41 | |
No. of Inverter Compressors | 1 | 1 | 1 | 1+1 | 1+1 | 1+1 | |
![]() | ![]() |
Indoor Type | Capacity (kbtu/h) | Application Considerations | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5.8 | 7.5 | 9.5 | 12 | 15 | 18 | 24 | 30 | 36 | 42 | 48 | 54 | 72 | 96 | |||
Ducted | FXMQ_PBVJU HSP DC Concealed Ducted Unit (High Static) | |||||||||||||||
FXMQ_TBVJU HSP DC Concealed Ducted Unit | ||||||||||||||||
FXSQ_TAVJU MSP Concealed Ducted Unit | ||||||||||||||||
FXSQ_TBVJU MSP Concealed Ducted Unit | ||||||||||||||||
FXSQ_TBVJU MSP Concealed Ducted Unit | ||||||||||||||||
FXDQ_MVJU LSP Slim Concealed Ducted Unit (Low Static) | ||||||||||||||||
FXTQ_TAVJU Multi-Position Air Handling Unit (Upflow, Downflow, Horizontal Left and Horizontal Right) | ||||||||||||||||
FXMQ_MVJU HSP High Capacity Concealed Ceiling Unit | ||||||||||||||||
FXNQ_MVJU9 Concealed Floor- Standing Unit | ||||||||||||||||
Non-Ducted | FXFQ_TVJU Round Flow Sensing Cassette, Ceiling Mounted | |||||||||||||||
FXUQ_PAVJU 4-Way Ceiling-Suspended Cassette | ||||||||||||||||
FXZQ-TBVJU VISTA 2x2 Cassette Unit for VRV | ||||||||||||||||
FXZQ_TAVJU VISTA 2x2 Cassette for VRV | ||||||||||||||||
FXEQ_PVJU Ceiling-Mounted Cassette (Single Flow) | ||||||||||||||||
FXHQ_MVJU Ceiling-Suspended Unit | ||||||||||||||||
FXAQ_PVJU Wall-Mounted Unit | ||||||||||||||||
FXLQ_MVJU9 Floor-Standing Unit | ||||||||||||||||
Zoning | Zoning Assembly for FXMQ_PVJU DZK Zoning Kit |