Products

Air-Cooled
Systems

A highly efficient, flexible HVAC solution designed to provide precise temperature control by adjusting refrigerant flow for each zone. These systems feature compact outdoor units that simplify installation, minimize energy consumption, and operate quietly, making them ideal for multi-zone buildings requiring tailored comfort in each space.

VRV IV

Daikin VRV IV Heat Pump units power up to 34 tons of capacity from a single piping network, with up to 64 indoor fan coil units, integrated controls and BMS options and piping flexibility never before seen with a DX system. Available in 460V/3Ph/60Hz or 208-230V/3Ph/60Hz.
Overview
Features
Technology
Lineup
Resources

Daikin’s VRV IV systems integrate advanced technology to provide comfort control with maximum energy efficiency and reliability. Currently available in heat pump and heat recovery configurations,VRV IV provides a solution for multi-family residential to large commercial applications desiring heating or cooling. The VRV IV is the first variable refrigerant flow (VRF) system to be assembled in North America.

What’s new about VRV IV?

Optimized Installation with New Unit Ranges for low total Life Cycle Cost (LCC)
Larger capacity single modules now range up to 14 tons. Modules can be combined to provide up to 34 tons from three modules on a single piping network, saving installation cost by reducing piping and electrical connections. Plus, system components allow flexibility to handle future building changes while minimizing retrofit requirements.

ventilation
Ventilation

Energy Efficiency with Variable Refrigerant Temperature (VRT)
VRV IV’s revolutionary Variable Refrigerant Temperature control automatically adapts to the unique requirements of your building and climate, significantly reducing seasonal operational cost compared to VRV III. Customize your operation between Automatic Mode, High Sensible Mode or Basic Mode to suit the application’s needs. 

itm-bacnet
System Controllers

Fast Installs mean Fast Commissions
VRV IV’s new commissioning tool enables designers to optimize system configurations to take advantage of new system capabilities, as well as new products from Daikin. This allows actual system settings to be optimized for comfort and energy savings from installation, reducing commissioning time.

 

Features

  • Total comfort solution for heating, cooling, ventilation and controls
  • Redesigned and optimized for total Life Cycle Cost (LCC)
  • Reduced install cost and increased flexibility as compared to VRV III with larger capacity single modules up to 14 tons and system capacity up to 34 tons
  • Efficiency improved over VRV III by an average of 11% with IEER Values now up to 28
  • Improved seasonal efficiency as compared to VRV III with automatic and customizable Variable Refrigerant Temperature (VRT) climate tuning
  • Best-In-class warranty* with 10-year compressor and parts limited warranty as standard
  • Reduced commissioning time vs. VRV III with VRV configurator software and Graphical User Interface (GUI)
  • Design flexibility with long piping lengths up to 3,280 ft. total and 100 ft. vertical separation between indoor units
  • Take advantage of Daikin’s unique zone and centralized controls

Technology

Daikin’s VRV IV systems integrate advanced technology to provide comfort control with maximum energy efficiency and reliability. Currently available in heat pump and heat recovery configurations, VRV IV provides a solution for multi-family residential to large commercial applications desiring heating or cooling. The VRV IV is the first variable refrigerant flow (VRF) system to be be assembled in North America.

Variable Refrigerant Temperature

 

VRV – Constantly Evolving, Setting the Standard.

VRV IV combines a number of substantial improvements in system capability and function compared to VRV III.

Larger capacity units now utilize new inverter compressors for all configurations. This improves overall efficiency and allows the VRV IV to start with essentially no inrush power. This is ideal for limiting demand expense and for solar installations or facilities that may occasionally run on generator power, where a high amperage starting requirement is difficult to meet.

VRV IV now uses a four-sided coil that presents a greater heat exchange surface. While allowing the same footprint for all unit sizes for ease of design, we have increased efficiency through improved heat transfer on all sizes. This change has also enabled increasing capacity in our standard modules, extending the range up to 34 tons on a single network. Many applications have been simplified, as fewer units can be used to achieve desired performance. Another added benefit to this is a reduction in system refrigerant volume.

Flexibility is everything

  • Large capacity range (6 – 34 ton), up to 64 indoor fan coil units on one system and up to 200% connection ratio
  • Long piping length, up to 3,280’ total, with up to 100’ vertical separation
  • Wide range of indoor units, including additional “mini-split” units
  • Redesigned and optimized for low total Life Cycle Cost (LCC)
  • All inverter compressors in all model sizes
  • New configuration software allows full setup offsite with PC upload
  • 10-year limited warranty* on compressor and parts is standard

* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 10-year compressor and parts limited warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.

Environment

  • Efficient overall system performance, up to 28 IEER
  • Excellent heating performance, up to 4.20 COP
  • Variable Refrigerant Temperature control cycle provides improved seasonal efficiency
  • Quieter than VRV III
  • Improved refrigerant leakage control
  • Reduced factory charge (refrigerant)

Comfort

  • All-inverter technology
  • Continuous heating during oil return
  • Night time quiet mode
  • Backup function

Installation Advantages

  • Light modular design
  • Common footprint
  • Automatic charge function
  • Automatic test and self-diagnosis functions
  • Improved electrical and refrigerant piping connections
  • Automatic information storage

Lineup

Capacity (TON)6810121416182022242628303234

208-230V & 460V and 575V

No. of Outdoor Units111112222222333
Max No. of Indoor Units121620252933374145495458626464
No. of Inverter Compressors (208-230V & 460V)111221+11+11+11+22+22+22+21+1+11+1+21+2+2
No. of Inverter Compressors (575V)111111+11+11+11+11+11+11+11+1+11+1+11+1+1
  

Indoor Units

Indoor TypeCapacity (kbtu/h)5.87.59.51215182430364248547296Application Considerations
Ducted

FXMQ_PBVJU
HSP DC Concealed Ducted Unit (High Static)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  High airflow/Low sound
Up to 0.8" ESP
Less than 12" height
MERV filtration

FXMQ_TBVJU
HSP DC Concealed Ducted Unit

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  High airflow/Low sound
Up to 0.8" ESP
Less than 10" height
MERV filtration

FXSQ_TAVJU
MSP Concealed Ducted Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Low sound level
auto fan speed control
Up to 0.6" ESP
Less than 10" height

FXSQ_TBVJU
MSP Concealed Ducted Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Low sound level
auto fan speed control
Up to 0.6" ESP
Less than 10" height

FXDQ_MVJU
LSP Slim Concealed Ducted Unit (Low Static)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       Hotels/Dorms
Rear or bottom suction
return Less than 8" height

FXTQ_TAVJU
Multi-Position Air Handling Unit (Upflow, Downflow, Horizontal Left and Horizontal Right)

DMVT Series   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  Replacement/Retrofit
Residential/Multi-family
Auto fan logic

FXMQ_MVJU
HSP High Capacity Concealed Ceiling Unit

            

 

 

 

 

 

 

Large/Open plan areas
Up to 0.95" ESP
MERV filtration

FXNQ_MVJU9 Concealed
Floor- Standing Unit

 

 

 

 

 

 

 

 

 

 

 

 

       Concealed installtions
Under window installations
Less than 9" depth
Non-Ducted

FXFQ_TVJU
Round Flow Sensing Cassette, Ceiling Mounted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   Open plan areas
Classrooms/Retail
Multiple airflow patterns

FXUQ_PAVJU 4-Way Ceiling-Suspended Cassette

     

 

 

 

 

 

 

 

 

 

 

 

 

     Office/Retail
Energy efficient fan motor
Stylish unit
Air temperature sensor

FXZQ-TBVJU
VISTA 2x2 Cassette Unit for VRV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

        Office/Retail
Low sound level
Three auto swing positions
Less than 12" height

FXZQ_TAVJU
VISTA 2x2 Cassette for VRV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

        Office/Retail
Low sound level
Independently motorized louvers
Less than 12" high

FXEQ_PVJU
Ceiling-Mounted Cassette (Single Flow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       Hotel Rooms / Offices / Residential (Apartments,Condominiums, etc.)

FXHQ_MVJU
Ceiling-Suspended Unit

   

 

  

 

 

 

     Narrow/Retrofit installations
Less than 8" height
Wide airflow

FXAQ_PVJU
Wall-Mounted Unit

 

 

 

 

 

 

 

       Compact, flat panel design
Auto swing for wide air
discharge

FXLQ_MVJU9
Floor-Standing Unit

 

 

 

 

 

 

 

 

 

 

 

 

       Replacement/Retrofit
Under window installations
less than 9" depth
Zoning

Zoning Assembly for FXMQ_PVJU DZK Zoning Kit

  

 

 

 

 

 

 

 

 

 

   Adds Multi-Zone capability for 2-6 zones